Open Access
Issue
ND 2007
2007
Article Number 251
Number of page(s) 3
Section Shielding and dosimetry
DOI https://doi.org/10.1051/ndata:07109
Published online 17 June 2008
International Conference on Nuclear Data for Science and Technology 2007
DOI: 10.1051/ndata:07109

Integral test of natural tungsten for CENDL-3.1

Liu Ping

China Nuclear Data Center, China Institute of Atomic Energy, P.O. Box 275(41), Beijing 102413, P.R. China

This email address is being protected from spambots. You need JavaScript enabled to view it.

Published online: 21 May 2008

Abstract
Integral experiment testing was carried out for neutron leakage spectra experiment from 40-cm tungsten pile and criticality experiment with tungsten reflector using the continuous-energy Monte Carlo code MCNP and the different natural tungsten data generated from CENDL-3.1, FENDL-2.0, ENDF/B-VII and JENDL-3.2. From the benchmark test results, we can say that neutron leakage spectrum obtained with CENDL-3.1 shows good agreement with experimental measurement below 5 MeV, but the leakage spectra at 5 ~ 13 MeV were underestimated with CENDL-3.1, JENDL-3.2 and ENDF/B-VII, especially the CENDL-3.1, but FENDL-2.0 gives better result in this energy range. For criticality experiment, CENDL-3.1 underestimates criticality by 514 pcm. Further improvement need to be made for tungsten in CENDL-3.1.